ETAP Level 3
The ETAP Level 3 Training Course at Burrāq UK is an advanced, industry-focused program designed for electrical engineers and professionals aiming to master complex power system analysis and design using ETAP (Electrical Transient Analyzer Program) software.
Aim of ETAP Level 3
The aim of the ETAP Level 3 Training Course is to develop advanced expertise in power system modeling, analysis, and protection coordination using the full capabilities of ETAP software. This course is designed for professionals who already have a foundational understanding of ETAP and want to perform high-level simulations and system studies aligned with real-world engineering challenges.
Course Overview
ETAP Level 3
Total Modules 10
Training Credits 30
Directed Learning Hours (DLH) 350
Course Code BUK1135
Educational Requirements:
- Minimum: Diploma of Associate Engineering (DAE) in Electrical / Electronics
- Preferred: Bachelor’s Degree in Electrical Engineering, Power Engineering, or a related discipline
Professional Requirements:
- Mandatory:
- Successful completion of ETAP Level 1 & Level 2 (or equivalent knowledge and experience)
- Familiarity with electrical single-line diagrams, system modeling, and basic protection schemes
- Preferred:
- 1+ year of experience in power system design, operations, or protection engineering
- Working knowledge of power distribution, industrial systems, or utility networks
| Course Code | Curriculum Title | Credit | DLH |
|---|---|---|---|
| BUK1752-1 | UDM Graphic Logic Editor | 30 | 35 |
| BUK1752-2 | DC Control System Design | 30 | 35 |
| BUK1752-3 | AC Control System Design | 30 | 35 |
| BUK1752-4 | Real Time System | 30 | 35 |
| BUK1752-5 | Switching Optimization | 30 | 35 |
| BUK1752-6 | Switching Sequence Management | 30 | 35 |
| BUK1752-7 | Power Management System | 30 | 35 |
| BUK1752-8 | Advance Distributed System | 30 | 35 |
| BUK1752-9 | Railway Traction System | 30 | 35 |
| BUK1752-10 | Motor Circuit Modelling | 30 | 35 |
Learning Objectives
- UDM Graphic Logic Editor
- Designing Generator Exciter System in UDM GLE
- Geospatial Diagram
- Connecting Geospatial Diagram to Maps
- DC Control System Design
- AC Control System Design
- Designing AC and DC Control Systems
- Real Time System
- Local Allocation
- Voltage Var Optimization and Voltage Control
- eTrax Analysis
- Switching Sequence Management
- Fault Management and service Restoration Mode
- Switching Optimization
- Optimal Capacitor Placement
- Reliability Assessment
- Optimal Power Flow
- Voltage Stability
- Unbalance Short Circuit
- Time Domain Flow
- Integrated Smart Grid Solution
- Power Management System
- Advance Distributed System
- Microgrid Master Controller
- Intelligence control enterprise hardware
- Railway Traction System
- Data Exchange
- Field Data Collector
- etapAPP Manager
- NetPM
- Synchro check relay concepts
- Synchro check relay concepts
- Auto reclosure concept ETAP case studies
- Ground Fault Protection
- Motor Circuit Modelling
- Scada Integrator
- State Estimation
- Real Time server
- ETAP Enterprise Solution
- Real Time Project
This Course is Ideal for:
- Electrical Engineers
- Protection Engineers and Relay Technicians
- Power System Analysts and Consultants
- DAE Professionals (Electrical)
- Senior Engineering Students or Graduates
- All Modules within this qualification are assessed internally by the approved training Centre and externally verified by BURRAQ UK. The program uses a criterion-referenced assessment approach to ensure that learners successfully meet all required learning outcomes.
- A Pass in any unit is granted only when the learner submits valid, reliable, and authentic evidence that demonstrates achievement of the assessment criteria. The Assessor is responsible for reviewing this evidence and confirming that the learner has attained the expected standard.